Cleaning Granules

The use of snail cleaners ensures a quick start to production and trouble-free manufacturing in injection molding, extrusion, and blow molding systems.

Screw cleaner can be used in a wide temperature range, so only one type is usually required, even for a wide range of materials. It is quick and easy to use, simple to handle, and completely non-toxic.

What are the advantages over competition?

  • Easy to use, no mixing of materials required
  • No need to change temperatures
  • Low smoke formation
  • Odorless
  • Lower material consumption
  • Cost-efficient
  • Sustainability (up to 30% recycled content/lower CO2 emissions)
  • Can be used as a shut-off mixture (sealing)
  • Suitable for hot runners
  • Parts can be injection molded with the cleaner
  • Contains no abrasive substances such as glass fiber or glass powder
  • Made in Germany

 

Injection molding and extrusion

  • Fast & gentle on the screw
  • Reduced smoke formation
  • Odorless
  • Cost-efficient
  • Sustainable

 

Top-Quality Made in Germany

 

Hinweis!
Das folgende Video wird von Youtube eingebettet.
Durch Streaming gelten die Datenschutzerklärungen von YouTube (Google)
schneckenputzer.de
Hinweis!
Das folgende Video wird von Youtube eingebettet.
Durch Streaming gelten die Datenschutzerklärungen von YouTube (Google)
schneckenputzer.de

 

Geeignet für alle Thermoplaste im Verarbeitungsbereich von 180-330 Grad

  1. Empty the cylinder completely and spray it out.
  2. The temperature of the cylinder does not need to be changed. Use the temperature of the material to be cleaned (the operating temperature of 180-330 degrees Celsius must be maintained).
  3. Please ensure that the cylinder inlet and the filling funnel are completely clean.
  4. Fill the funnel with Turbo screw cleaner. The material should not be mixed.
  5. Convey the material at low back pressure until the cleaner visibly emerges from the nozzle.
  6. Dose the cleaner at increased back pressure and high screw speed. In case of heavy soiling, you can leave the cleaner to work for approx. 5 minutes
    (do not leave Turbo screw cleaner in the cylinder for longer than 20 minutes).
  7. Dose several times and spray until the contaminants or paint are no longer visible in the sprayed cleaner.
  8. Then completely empty the cylinder under high back pressure.
  9. Set the temperature in the cylinder to the next polymer.
  10. If the machine is not in use for a longer period of time, the Turbo screw cleaner can also be used as a freezing mixture to prevent deposits on the screw and in the cylinder.


Safety instructions: Wear safety goggles and gloves. Packaging CO2 neutral, made from PCR PP.

 

 

Request information

 

 

  |  top  |